Product Details

Place of Origin: china

Brand Name: GCE

Certification: CE

Model Number: RBMS-S37-250A-350

Document: GCE HV BMS 4U center tap RB...on.pdf

Payment & Shipping Terms

Minimum Order Quantity: 2 uints

Price: $1065

Packaging Details: Cardboard box foam packaging

Delivery Time: 25 workdays

Payment Terms: L/C, T/T

Supply Ability: 1000 units per month

Chat now
Highlight:

GCE BMS High Voltage 80S 256V

,

UPS Battery Management System with CAN RS485

,

High Voltage BMS with TCP/IP

Product Name:
Battery Management System BMS
Suitable Battery Type:
Lithium Batteries,LFP/NMC/LTO
Communication:
RS485/CAN/TCPIP
Warranty:
3 Years
Weight:
22kg
Size:
482*180*500(mm)
BMS Type:
Master-slave BMS Architecture
Capacity:
100Ah/150Ah/200Ah/280Ah/314Ah/any Capacity
Current:
125A,160A, 250A(Optional)
Max Voltage:
350V,750V,1000V(Use According To Rated Voltage Match)
Balancing Tech:
Active/passive Balance(Optional)
Application:
Ups Backup Power Supply
Product Name:
Battery Management System BMS
Suitable Battery Type:
Lithium Batteries,LFP/NMC/LTO
Communication:
RS485/CAN/TCPIP
Warranty:
3 Years
Weight:
22kg
Size:
482*180*500(mm)
BMS Type:
Master-slave BMS Architecture
Capacity:
100Ah/150Ah/200Ah/280Ah/314Ah/any Capacity
Current:
125A,160A, 250A(Optional)
Max Voltage:
350V,750V,1000V(Use According To Rated Voltage Match)
Balancing Tech:
Active/passive Balance(Optional)
Application:
Ups Backup Power Supply
GCE BMS High Voltage 80S 256V +- 128V 3-Wire Center-Tap 700V 250A UPS Battery Management System Neutral CAN RS485 TCP/IP OEM ODM
High Voltage Rack Battery Management System (RBMS)
Industrial-grade 3-wire center-tap BMS designed specifically for UPS and energy storage systems with neutral line requirements. Supports up to 750V voltage classes and 250A continuous current.
Product Overview
The 4U High Voltage Rack Battery Management System (RBMS) is a highly integrated, industrial-grade BMS designed specifically for 3-wire (center-tap / neutral-line) UPS and energy storage systems. It delivers seamless monitoring, robust protection, and flexible communication to safeguard large-scale lithium battery packs in demanding commercial and industrial environments.
Supporting voltage classes up to 750V (260-750 VDC operating range) and continuous currents of 125A / 160A / 250A, this RBMS is the backbone of reliable battery clusters for UPS power supply, PV plant storage, micro-grids, and 220V DC power systems.
Applications
PV Plant Storage - Grid-tied and off-grid solar energy storage for utility-scale projects
UPS Power Supply - 3-wire center-tap configuration purpose-built for UPS with neutral line
Industrial & Commercial ESS - Peak shaving, backup power, and demand management for C&I facilities
Island / Off-Grid Storage - Standalone power systems for remote areas without grid access
Micro-Grid Applications - Distributed energy resource management and local grid stabilization
Power System 220V DC - Telecom and substation 220V DC backup power supply systems
Key Features
  • 3-Wire Center-Tap Architecture - Purpose-built for systems requiring a neutral line (B+ / N / B- and P+ / N / P-), ensuring safe and balanced operation with UPS and center-tap inverters
  • Advanced Integrated BMS - Highly integrated battery management enables seamless real-time monitoring of every cell, module, and system-level parameter
  • Self-Check & HMI Display - Comprehensive self-diagnosis and operating-status detection, paired with an optional 4.3" or 7" external HMI screen for at-a-glance system visibility
  • Multi-Level Protection - Reliable control and protection strategies (OVP, UVP, OTP, OCP, SCP) extend pack life and ensure personnel safety. Short-circuit protection: 1000V / 25kA / 20ms
  • Modular & Scalable - Multiple energy storage units can be flexibly combined. Supports up to 256 cells in series (400S for lead-carbon batteries)
  • Rich Communication Interfaces - CAN, RS485, Ethernet (TCP/IP), and dry-contact I/O. Compatible with most PCS, Inverters, UPS, and monitoring servers on the market
  • Flexible Protocols - Ships with the factory communication protocol; custom protocol adaptation for different brands of PCS / Inverter / UPS is available on request
  • High-Capacity Data Logging - Built-in large-capacity memory chip stores critical operational data. Optional SD card for historical cell-level data archiving
  • Parallel Operation Ready - Automatic circulation control and automatic parallel / offline control support multi-cluster systems (up to 15 RBMS units via ID DIP switches)
  • Dual Power Supply - Supports battery + mains AC input (85-264 VAC, ≤1A) with mains-priority logic. Must be taken from the UPS output side
GCE BMS High Voltage Rack System front view GCE BMS internal components and wiring GCE BMS installation in rack cabinet GCE BMS interface and connection details
Model Naming Guide
Format: RBMS -- S/D -- 2/3 -- 0/4/7 -- XXXA -- XXX
Position Code Meaning
1 RBMS Rack Battery Management System
2 S / D S = Standalone (2-level: BMU+RBMS); D = Multi-cluster Parallel (3-level: BMU+RBMS+SBMS)
3 2 / 3 2 = Two-wire system; 3 = Three-wire (center-tap) system
4 0 / 4 / 7 0 = No screen; 4 = 4.3" HMI display; 7 = 7" HMI display
5 125A / 160A / 250A System rated current
6 350 / 750 / 1000 Voltage class: 350 = 120-350VDC; 750 = 260-750VDC; 1000 = 500-1000VDC
Example: RBMS-D37-250A-750 = Parallel-ready, 3-wire, 7" display, 250A rated, 750V class.
Technical Specifications
Basic Parameters
Parameter Value / Range
Rated Current 125A / 160A / 250A (optional)
Voltage Class 350V (120-350VDC) / 750V (260-750VDC) / 1000V (500-1000VDC)
Max Voltage Matched to rated voltage class
Power Consumption ≤25W (3-wire system); ≤15W (2-wire system)
Current Sampling Accuracy 1% FSR
Insulation Withstand Voltage 2800VDC, <1mA, 1min
Protection Level IP20
Dimensions (W×H×D) 482 × 180 × 500 mm
Net Weight ~22 kg
Installation Standard 19-inch rack mount, front-in / front-out
Operating Temperature -20℃ ~ +45℃ (derate above 45℃)
Operating Humidity 5% ~ 75% RH
Appearance / Color RAL9005 Black Sand Texture
Communication Ports
Port Interface Function
BMU-OUT CAN Communication with BMU; cascade BMU communication
COM-IN / COM-OUT RS485 / CAN Parallel: communicate with SBMS; Standalone: communicate with UPS/PCS external equipment
TCP/IP Ethernet (RJ45) PC connection for upper-computer software; CAT5 or above
HMI-A / HMI-B / 24V / GND 3.81-4Pin External HMI display connection / SBMS power supply
D1 D2 Dry Contact (NO) 2-channel dry contact output for charge / discharge prohibition signals
Basic Functions
Function Status Details
Battery Charge & Discharge Management Supported Automatic charge/discharge control with configurable thresholds
Battery Temperature Management Supported Multi-point temperature monitoring and protection
IAP Upgrade Supported In-Application Programming for firmware updates
System Protection Parameters Supported User-configurable protection settings
Short-Circuit Protection Supported 1000V / 25kA / 20ms
Pre-Charge Function Supported Pre-charge circuit for safe inverter/UPS connection
Parallel Circulation Control Supported Automatic current sharing in multi-cluster setups
Event Record Supported Up to 5000 event logs
3-Wire Center-Tap System Supported (Optional) B+ / N / B- and P+ / N / P- power terminals
Dual Power Supply Supported Battery + AC mains (85-264VAC, ≤1A); mains priority
Safety & Certifications
Standard Description
CE IEC 62477-1, EN 61000-6-2 / EN 61000-6-4
GB/T GB/T 16935.1, GB/T 17626.2, GB/T 17626.5
Optional Functions
  • Insulation Detection - Applicable to systems ≥300V
  • HMI Display - 4.3" or 7" external display (optional)
  • Standalone / Parallel - Configured before shipment
Interface Description
No. Name Description Precautions
1 B+ / N / B- Battery-side power terminals (total positive, neutral, total negative) For 2-wire systems, do NOT connect N. Bolt: M8×16, torque 8-12N*m; cable ≥70mm² (2/0AWG) copper
2 P+ / N / P- Load-side power terminals to UPS / DC bus For 2-wire systems, do NOT connect N. Bolt: M8×16, torque 8-12N*m; cable ≥70mm² (2/0AWG) copper
3 AC Input Mains AC power input (85-264VAC, ≤1A max) Must be taken from the UPS output side. Wire: 1.0mm² (18AWG)
4 ON / OFF Circuit breaker handle ON = closed; OFF = disconnected. If tripped, reset to OFF first before re-closing
5 D1 / D2 2-channel dry contact output (NO) Charge prohibition / discharge prohibition signals
6 Start DC start button Press after breaker closure; LED lights = system powered on
7 System System status LED Green steady = normal; Yellow steady = alarm; Red steady = fault/protection; Green flash = charging; Red flash = discharging; Red/Green alt = self-check; Yellow flash = pre-charging
8 ID DIP Switch 4-bit DIP switch for parallel ID allocation Must start from 1. Supports up to 15 RBMS units in parallel
9 TCP/IP Ethernet port for PC upper-computer software CAT5 or above; straight or crossover cable (TIA-568A / TIA-568B)
10 T-CAN / T-485 Termination resistor switches (120Ω) Parallel: set only on the last unit. Standalone: set based on interference / distance
11 COM-IN / COM-OUT External communication ports Must use the supplied twisted-pair shielded cable harness
12 HMI-A / HMI-B / 24V / GND External display / SBMS power interface Connect display according to silkscreen sequence
13 BMU-OUT BMU communication interface Cascade communication with BMU modules
14 Ground Chassis grounding point Must be reliably grounded; grounding resistance <1Ω
Dimensions & Installation
  • Dimensions (W × H × D): 482 × 180 × 500 mm
  • Mounting: Standard 19-inch rack rails (4U height)
  • Cable Routing: Front-in / front-out design for easy maintenance in standard server cabinets
  • Weight: ~22 kg
  • Clearance: Ensure adequate ventilation; derate output above 45℃ ambient
The 3-wire (center-tap) model includes additional N (neutral) terminals on both battery side (B+ / N / B-) and load side (P+ / N / P-). This configuration is purpose-built for UPS systems that require a neutral line connection.
Safety Precautions
High voltage inside. Only authorized technicians may open the chassis. Unauthorized disassembly voids warranty and risks.
  • After secondary protection trips, power off the system, clear the fault, and wait at least 1 minute before restarting to allow the circuit breaker shunt coil to cool
  • When cold-starting a PCS / Inverter / UPS from the battery, close the battery switch on the PCS side before starting the RBMS. Closing a charged battery into a large DC-bus capacitor can cause contactor arcing and welding
  • Installation and commissioning personnel must use insulated tools
  • For maintenance, disconnect the RBMS main circuit breaker to isolate the battery pack from the DC bus
  • Charging/discharging current and voltage parameters are factory-set during commissioning. Do not change them without authorization
  • In case of fire, use dry powder extinguishers or fire sand only
  • If the system will be idle for a long time, disconnect the main circuit breaker of the battery cabinet
  • Avoid prolonged use in environments exceeding specified temperature/humidity, with strong vibration, direct sunlight, dust, corrosive substances, or high salt fog
Standard Accessories
Name Specification Qty
Power Terminal Sheath (Black) Black 4 pcs (3-wire model) / 2 pcs (2-wire model)
Power Terminal Sheath (Orange) Orange 2 pcs
External Communication Cable 6-core shielded, 2 meters 1 pc
AC Socket (Wireable) 250V 10A 1 pc
Dry Contact Terminal 5.08-4Pin 1 pc
Terminating Resistor 120Ω 1 pc
Display Terminal 3.81-4Pin 1 pc
Frequently Asked Questions
What is a 3-wire center-tap BMS, and do I need it?
A 3-wire (center-tap) BMS provides a neutral (N) terminal in addition to positive and negative, enabling balanced connection to UPS and inverters that require a neutral line. If your UPS or inverter specifies a center-tap / neutral-line battery connection, this model is required.
Is this BMS compatible with my UPS brand?
Yes. The RBMS supports RS485, CAN, and Ethernet communication. We provide our standard protocol by default, and we can adapt the communication protocol to match most major UPS, PCS, and inverter brands upon request.
What voltage and current options are available?
Voltage classes: 350V (120-350VDC), 750V (260-750VDC), and 1000V (500-1000VDC). Rated current options: 125A, 160A, or 250A. Contact us to configure the right model for your battery cluster.
Can multiple RBMS units work in parallel?
Yes. The RBMS-D (parallel) version supports up to 15 units in parallel via DIP-switch ID allocation, with automatic circulation control for safe current sharing across battery clusters.
Do you support OEM and ODM?
Absolutely. We offer full OEM/ODM services including logo customization, enclosure color, communication protocol adaptation, firmware feature development, and private-label packaging. MOQ and lead time depend on customization scope.
What certifications does this product carry?
CE certification (IEC 62477-1, EN 61000-6-2 / EN 61000-6-4) and compliance with Chinese national standards GB/T 16935.1, GB/T 17626.2, GB/T 17626.5.
Ready to Power Your Next Project?
Get a tailored quote for your specific voltage, current, and communication requirements.
We offer OEM / ODM, protocol customization, and global technical support.
Contact Us for a Quote
Hunan GCE Technology Co., Ltd. | jeffreyth@hngce.com | www.hngce.com