Product Details
Place of Origin: CHINA
Brand Name: GCE
Certification: CE UL TUV
Model Number: RBMS07-S30-50A384V
Payment & Shipping Terms
Minimum Order Quantity: 2
Price: Negotiatable bruceliu@hngce.com
Packaging Details: Bubble bag, foam, carton
Delivery Time: 20-25 days
Payment Terms: T/T, L/C
Supply Ability: 1000sets/month
Warranty: |
3 Years |
Application: |
UPS, ESS, Solar Off-Grid BESS |
Type: |
Center Tapped Model |
Cell Type Applicable: |
Lifepo4 NCM LTO |
Design Feature: |
AC DC Daul Power Supply |
Voltage: |
384V |
Curret: |
50A |
Communication: |
LAN, RS485, CAN |
Warranty: |
3 Years |
Application: |
UPS, ESS, Solar Off-Grid BESS |
Type: |
Center Tapped Model |
Cell Type Applicable: |
Lifepo4 NCM LTO |
Design Feature: |
AC DC Daul Power Supply |
Voltage: |
384V |
Curret: |
50A |
Communication: |
LAN, RS485, CAN |
GCE +/-192V=384V 50A 120S cells Lithium high voltage ESS BMS lifepo4 BMS center tap&middle line&3-wire relay BMS breaker UPS
GCE HV Overall Solution BMS Configuration:
For UPS Power manufacturer, the Overall solution center-tapped BMS with flexible and strong
configurability, its dual battery cluster backup means double protection on the continuous power
supply to clients. BMS can adapt to the requirements of UPS for the environment and perform
tasks such as battery protection and continuous power supply. It is a good helper for solving problems.
One set of +/-192V=384V 50A 120S contains:
1unit Master BMS, model#: RBMS07-S30-50A384V
8units Slave BMU, model#: BMU07-15S8T48F
8set 15S Wire Harness.
The main control will be required if there are multiple racks parallel connection, model#: SBMS, which is
equipped with a 7" touchscreen.
GCE HV Master BMS and Accessories:
![]() |
12S-24S BMU(Slave) 12S-24S BMU has 8pcs of temperature sensors, Fan voltage 48V(17S-24S 12V), voltage detection range 0-5V,12V power supply, consumption less 20mA, CAN2.0 B communication
Wire harness- Signal acquisition wire 18 P+20P wire, standard length 600mm,900mm,1200mm temperature sensor wire: standard length: 600mm,900mm,1200mm Fan Power wire: 600mm
Wire harness- communication wire Communication wire connects from the master BMS to each BMU with a cascade connection, the last port is for terminal resistance |
GCE BMS technical parameters:
RBMS(master BMS) | 4U-125A/160A/250A |
protecting method | MCCB+Contactor |
Rated Current range | -250A~250A |
Voltage range | 384V-1000V |
Current sampling accuracy | 1.0%FSR |
Communication interface with PCS | RS485/CAN |
Communication interface with BMU | CAN |
Communication interface with GBMS | RS485/CAN |
Communication with monitoring software/EMS | Ethernet |
Support IAP upgrade | Yes |
Support HMI display and parameter settings | No(OptionalPlug in) |
Insulation detection | Yes(Optional) |
High voltage power module | Support DC start (optional) |
Dry contact output (normally open) | None |
Maximum qty of BMUs | 18 |
Power | 24VDC(18~28V) |
Power consumption | ≤25W |
Size (W*H*D)mm | 4U |
(440*178*500) | |
Connection Way out | Back and front |
Tap center | support(optional) |
net weight | 23kg |
Applications:
![]() |
![]() |
![]() |
![]() |
FAQs:
GCE HV BMS Documents Download:
Linkage for downloading Master BMS and Slave BMU specifications:
GCE_RBMS specification--EN--V1.0.pdf
GCE 12-16S BMU-specification-UL-V1.0.pdf
Linkage for downloading a BMS demand information collection form:
high voltage BMS info collection form EN2021-04.do...