Hunan GCE Technology Co.,Ltd
jeffreyth@hngce.com 86-731-86187065
Products
Products
Home > Products > Master Slave BMS > BMS High Voltage Battery Management System 96S307.2V HV BMS 125A For Stationary ESS UPS High Voltage Lithium Batteries

BMS High Voltage Battery Management System 96S307.2V HV BMS 125A For Stationary ESS UPS High Voltage Lithium Batteries

Product Details

Place of Origin: China

Brand Name: GCE

Certification: CE/ROHS/MSDS

Model Number: RBMS-S20-125A-307.2V

Payment & Shipping Terms

Minimum Order Quantity: 2 Set

Price: Negotiable

Packaging Details: Corrugated Carton, bundles, pallets, wooden box

Delivery Time: 15-20 days

Payment Terms: FOB/CFR/EXW

Supply Ability: 5000pcs / month

Chat now
Highlight:

High Voltage BMS for lithium batteries

,

96S307.2V HV BMS 125A

,

Master Slave BMS for ESS UPS

Features:
DC&AC Dual Power Supply
Voltage:
307.2V
Color:
Black
System Protection Parameter Setting:
Support
Compatible Inverter:
Deye, Growatt, Goodwe, Sofar, Atess, Sungrow, Bluesun...
Insulation Withstand Voltage:
2800VDC <1mA 1min
Operating Ambient Temperature:
-20℃~60℃
Current:
125A
Parameter Setting:
Available
Communication Protocol:
CAN
Mounting Type:
19" Rack
Dimension:
440mm*178mm*500mm
Style:
Slave And Master All In One Device
Strings:
96S
Structure:
3-level Structure
Display:
3.5-inch
Cell Balancing Method:
Passive
Product Type:
Battery Management System
Features:
DC&AC Dual Power Supply
Voltage:
307.2V
Color:
Black
System Protection Parameter Setting:
Support
Compatible Inverter:
Deye, Growatt, Goodwe, Sofar, Atess, Sungrow, Bluesun...
Insulation Withstand Voltage:
2800VDC <1mA 1min
Operating Ambient Temperature:
-20℃~60℃
Current:
125A
Parameter Setting:
Available
Communication Protocol:
CAN
Mounting Type:
19" Rack
Dimension:
440mm*178mm*500mm
Style:
Slave And Master All In One Device
Strings:
96S
Structure:
3-level Structure
Display:
3.5-inch
Cell Balancing Method:
Passive
Product Type:
Battery Management System
BMS High Voltage Battery Management System 96S307.2V HV BMS 125A For Stationary ESS UPS High Voltage Lithium Batteries
3U 125A Two-Wire RBMS High Voltage Rack BMS with 3.5" HMI for PV ESS & UPS Energy Storage
high voltage RBMS rack battery management system solar storage BMS 3U 125A BMS LiFePO4 BMS off-grid ESS BMS industrial UPS BMS multi-cluster parallel BMS CAN RS485 communication BMS 350V 600V energy storage BMS
3U RBMS High Voltage Battery Management System
Brief Overview

Developed by Hunan GCE Technology, this 3U rack-mount RBMS is a distributed high-voltage battery master controller tailored for lithium energy storage projects. Supporting standalone two-tier and multi-rack three-tier control architectures, it handles max 125A continuous current with dual voltage grades (350VDC / 600VDC). Built-in 3.5-inch embedded touch display delivers real-time system diagnostics, while multi-channel CAN/RS485/Ethernet ports enable plug-and-play linkage with mainstream inverters, UPS, and central stack SBMS. CE & RoHS certified, modular, expandable up to 15 parallel racks, ideal for residential, commercial & utility-scale solar storage deployments.

RBMS System Architecture Diagram
Brand & Manufacturer Introduction

Hunan GCE Technology (Group Control Energy, GCE) is a China-based professional high-voltage lithium BMS manufacturer with over a decade of R&D and mass production experience. We focus on rack-level cluster battery management solutions compatible with LiFePO4, NMC, and LTO lithium chemistries, covering a DC operating voltage range from 96V to 864V. Our factory owns complete hardware & firmware development lines, offering flexible OEM & ODM customization for global energy storage integrators, solar installers, and UPS manufacturers. All products pass strict pre-delivery aging tests and comply with IEC & national GB safety standards.

Hunan GCE Technology Manufacturing Facility
Core Product Advantages
  • Dual System Architecture Design: Two operating modes for flexible deployment: standalone single rack (2-layer: BMU+RBMS) or multi-rack parallel system (3-layer: BMU+RBMS+SBMS). Max support 15 racks in synchronous parallel with a built-in automatic circulation balance algorithm to eliminate cross-current risks. Up to 160 cells in series, monitoring for high-voltage battery clusters.
  • All-Round Safety Protection Mechanism: Integrated pre-charge circuit, 20kA/20ms short-circuit cut-off, overvoltage/undervoltage/overtemperature lockout, secondary fault interlock. 2800VDC insulation withstand capability; optional insulation resistance detection for systems over 300V. IP20 cabinet protection for indoor 19-inch standard rack installation.
  • Rich Multi-Channel Communication Compatibility: Equipped with isolated CAN, dual RS485, and RJ45 Ethernet interfaces. Native GCE communication protocol, customizable to match third-party PCS, inverter, and UPS brands. Two dry-contact signal outputs for charge/discharge prohibition alarms; stores up to 5,000 system fault logs, expandable with an external SD card for long-term cell data recording.
  • Intuitive Local & Remote Monitoring: Factory-fitted 3.5-inch embedded HMI screen displays real-time voltage, current, temperature, and fault codes. Multi-color LED indicator panel shows charging/discharging/pre-charge/alarm/self-test status. PC upper monitoring software is accessible via Ethernet for remote parameter calibration and IAP firmware online upgrade.
  • Wide Environmental Adaptability & Compact Structure: 3U standard rack size (482×132×500mm, net weight ~16kg), front-in & front-out wiring design for easy cabinet maintenance. Operating temperature: -20℃ ~ 55℃, auto current derating above 55℃ to extend service life; 5%-75%RH humidity working range without condensation. Ultra-low standby power consumption ≤15W.
Complete Technical Parameter Table
Category Item Specific Parameter
Core Electrical Spec Rated Continuous Current 100A, peak instantaneous 125A
Optional DC Voltage Grade 350V (120-350VDC operating range) / 600V (260-600VDC operating range)
Static Power Consumption ≤15W
Current Sampling Precision ±1%FSR
Insulation Dielectric Strength 2800VDC, leakage <1mA within 1min
Physical Spec Cabinet Dimension 482(W)*132(H)*500(D) mm, 3U standard 19-inch rack
Net Weight ~16 kg
Protection Class IP20 indoor use
Appearance RAL9005 black sand grain coating
Communication Interfaces BMU Sampling Link Isolated CAN bus
External Device Link (PCS/UPS/SBMS) Dual RJ45 COM ports (integrated CAN+RS485 isolated signals)
Remote PC Monitoring RJ45 Ethernet (CAT5e cable compatible)
Dry Contact Output Max 2-channel normally open alarm terminals
Built-In Standard Functions Charge & discharge full-cycle management Supported
Cell temperature real-time control Supported
Online IAP firmware upgrade Supported
Automatic parallel & circulation suppression Supported
Fault event storage 5,000 historical records
Pre-charge anti-spark circuit Supported
DC cold startup (battery-powered) Supported
Optional Custom Functions 3.5-inch embedded HMI display Factory pre-installed
High-voltage insulation detection For systems ≥300V
Multi-rack parallel function Pre-configured before shipment
Environmental & Compliance Operating Temp -20℃ ~ 55℃ (current derating above 55℃)
Working Humidity 5% ~ 75% RH, non-condensing
Certifications CE (IEC62477-1, EN61000-6-2/4), RoHS
Compliant with National Standards GB/T 16935.1, GB/T 17626.2, GB/T 17626.5
Application Scenarios

This 3U RBMS serves all mainstream lithium energy storage and backup power projects globally:

  • Renewable Solar Storage: Grid-tied PV power stations, off-grid island solar systems, wind-solar hybrid microgrids
  • Commercial & Residential ESS: Behind-the-meter self-consumption storage, household wall-mounted battery cabinets, small industrial energy storage
  • Backup Power Supply: Industrial-grade UPS for data rooms, telecom base stations, hospital & factory critical load power backup
  • DC Power Infrastructure: 220VDC power supply systems for power grid substation equipment
  • Utility Energy Regulation: Large-scale energy storage clusters for grid peak shaving & frequency modulation
RBMS Application in Energy Storage Systems
Product Naming Rule Explanation (Model Decoding)

Take model RBMS-D23-125A-600 as an example:

  • RBMS: Rack Battery Management System (cluster master BMS)
  • S/D: S=single standalone rack; D=multi-rack parallel support
  • 2: Two-wire internal wiring system
  • 3: Equipped with a 3.5-inch embedded HMI screen
  • 125A: Maximum allowable system rated current
  • 600: 600V voltage grade (260-600VDC working window)
Frequently Asked Questions
Q1: Are you a manufacturer or a trading company?
We are an original factory with an independent hardware & firmware R&D center and 10+ years of high-voltage BMS production experience. Factory inspection is warmly welcomed.
Q2: Can we order samples for performance testing?
Sample supply is available for clients to verify compatibility with local inverters and battery packs before a bulk order.
Q3: What lithium cell chemistries does this RBMS support?
Compatible with LiFePO4 (LFP), ternary NMC, and lithium titanate (LTO) battery modules, customizable to match the customer's cell voltage configuration.
Q4: How long is bulk order lead time?
The standard production cycle is 15-20 working days after deposit receipt, adjustable based on order quantity and custom functional demands.
Q5: What payment terms do you accept?
Mainly T/T advance deposit; other payment methods can be negotiated for long-term cooperative distributors.
Q6: Official warranty policy?
3-year full warranty for RBMS mainframe; 1-year warranty for matched BMU sampling boards and PCBA accessories.
Q7: Do you accept OEM & ODM customization?
Yes, we provide personalized service including communication protocol adaptation, casing logo printing, function parameter preset, and customized wiring terminals.
Q8: What inverter brands can this RBMS connect to?
All mainstream domestic and overseas PCS/inverter/UPS brands are supported; we will adjust internal communication protocols according to client equipment models free of charge.
Q9: How many racks can be operated in parallel at maximum?
4-bit DIP ID switch design supports synchronous parallel operation of up to 15 RBMS racks under one SBMS stack controller.
Q10: What's the maximum series cell count supported?
The system can be configured to monitor a maximum of 160 lithium cells connected in series for high-voltage large-capacity clusters.
Safety Operation Reminders
  • The product contains high-voltage circuits inside; disassembly without factory authorization will void the warranty and pose other hazards. Only certified GCE technicians are allowed to perform internal maintenance.
  • After the secondary protection circuit breaker trips, cut off total DC power and wait a minimum of 60 seconds before restarting to avoid damage to internal shunt coils.
  • When cold-starting UPS/PCS via battery power, close the DC switch on the inverter side first before activating RBMS to prevent contactor burnout caused by instantaneous capacitor charging surge current.
  • All installation tools must have fully insulated handles; cut off the RBMS main breaker completely before any wiring maintenance.
  • System charge/discharge protection parameters are preset per project demand; unauthorized parameter modification may trigger battery thermal runaway risks and shorten pack lifespan severely.
  • In case of fire near the energy storage cabinet, only dry powder fire extinguishers or fire sand are permitted; liquid fire-fighting agents will cause other potential hazards.
  • Disconnect the main circuit breaker if the whole storage system stays idle for long periods to avoid static power consumption draining battery capacity.
  • Avoid long-term deployment in environments with severe vibration, direct sunlight, heavy dust, corrosive gas or flammable materials.
RBMS Safety Installation Guidelines
Packing & Standard Accessories
  • Standard packing: Carton with shockproof foam inner padding
  • Included accessories: MPC120 red/blue power quick-plug terminals, 250V 10A AC wiring socket, 120Ω communication terminal resistors, 6Pin dry-contact wiring terminal, power terminal contact fittings
Supplier Commitment

As a trusted high-voltage BMS supplier for global energy storage integrators, GCE persists in strict full-process quality control covering raw material incoming inspection, assembly line aging testing, and full-function pre-shipment verification. Our professional technical team provides one-stop after-sales support, including wiring guidance, system debugging, and remote fault diagnosis, delivering stable, safe, and cost-effective rack BMS solutions for the rapidly expanding global renewable energy storage market.