Product Details
Place of Origin: CHINA
Brand Name: GCE
Certification: CE
Model Number: RBMS08-D75S-50A
Payment & Shipping Terms
Minimum Order Quantity: 2
Price: Negotiate with cara@hngce.com
Packaging Details: Bubble bag, foam, carton
Delivery Time: 15 days
Payment Terms: T/T, L/C
Supply Ability: 1000sets/month
|
Application:
|
Home Storage/off-grid/ESS/UPS/backup/Solar Energy Storage
|
Warranty:
|
3 Years For RBMS And 1 Year For BMU/PCBs
|
Voltage:
|
240V
|
Current:
|
50A
|
Dimensions:
|
480*433*100mm
|
Operating Tempreture:
|
-20~60℃
|
Charge/Discharge Current:
|
50A / 100A
|
Short Circuit Protection:
|
Yes
|
Style:
|
Slave And Master All In One Device
|
Power Consumption:
|
≤10W
|
Basic Module:
|
Max. 15S
|
Weight:
|
10kg
|
Color:
|
Black
|
ODM & OEM:
|
Acceptable
|
|
Application:
|
Home Storage/off-grid/ESS/UPS/backup/Solar Energy Storage
|
|
Warranty:
|
3 Years For RBMS And 1 Year For BMU/PCBs
|
|
Voltage:
|
240V
|
|
Current:
|
50A
|
|
Dimensions:
|
480*433*100mm
|
|
Operating Tempreture:
|
-20~60℃
|
|
Charge/Discharge Current:
|
50A / 100A
|
|
Short Circuit Protection:
|
Yes
|
|
Style:
|
Slave And Master All In One Device
|
|
Power Consumption:
|
≤10W
|
|
Basic Module:
|
Max. 15S
|
|
Weight:
|
10kg
|
|
Color:
|
Black
|
|
ODM & OEM:
|
Acceptable
|
GCE HV BMS Configuration:
One complete set of HV 75S240V 50A BMS includes:
Master BMS, Model#: RBMS08-D75S-50A, and its wire accessories, include 6p temperature sensing wires and 16p voltage sensing wires.
There are two different models for integrated BMS, one is a standalone model while the other one is parallel with its cost slightly higher than the standalone model.
![]()
![]()
![]()
![]()
GCE HV Integrated Master BMS and Accessories:
30-75S Integrated BMS
Voltage range:96V-240V
Current:50A/100A
Communication:CAN & RS485
Design: Master & slave all in one.
![]()
Temperature acquisition wire
Standard length is 600mm,900mm,1200mm
There are 3 temperature sensing probes per 15S wires. In total, there are 12 probes in 60S and 15 probes in 75S.
![]()
Voltage acquisition wire
Standard length is 600mm,900mm,1200mm
![]()
GCE integrated BMS Characteristics:
|
※ Perfect self-checking and running status checking function, with HMI display screen, system running information is clear at a glance.
|
※ Abundant communication interfaces---multiple RS485, CAN, Ethernet, dry contact input and output interfaces, supporting communication with most PCS and monitoring servers on the market. |
![]()
GCE integrated BMS Technical parameters:
| Item | Specifications and parameters | |
| System operating voltage range | 120 - 370 VDC | |
| Startup mode | DC start | |
| balance | Equilibrium type | Passive resistance equalization |
| Balanced current | 100mA ± 10mA (when cell at 3.50V) | |
| Sampling accuracy | ± 2℃ | |
| Voltage sampling | Sampling accuracy | single-cell ±20mV |
| Communication mode | Can: 1 channel (communication with PCs / UPS) | |
| RS485: 1 channel (communication with upper computer / PCS / UPS) | ||
| Display mode | 6-digit LED indicator, including | |
| 1-bit fault indication, 1-bit operation indication, 4-bit SOC power indication | ||
| HMI display: optional 3.5 inch | ||
| Rated current | 50A/100A | |
| (be selected according to customer needs) | ||
| Short circuit protection | Support 7.5KA 20ms | |
| Maximum overload capacity | 50A system transient: 70A/10S | |
| 100A system transient: 150A/10S | ||
| Alarm level | one Level | |
| Protection level | two levels | |
| Level 1 cut-off charge/discharge | ||
| Level 2 micro cut-off switch, system power down | ||
| Power consumption | ≤10W | |
| Weight | 4.5kg | |
| Withstand voltage rating | 1800VDC 1mA 1min | |
| Safety certification | Comply with CE certification standards | |
| Operating temperature | -20~60℃ | |
| Operating humidity range | <90 RH(40℃±2℃) | |
Download linkage of Specification:
GCE 30S-75S integrated BMS specification Ch-EN V2...
High Voltage BMS Application:
![]()
FAQs about GCE HV BMS: